This circuit provides charging current to the batteries.
When connected to shore power, main electricity provides electrical current which is converted to a battery-charging current through a charger. This arrives at a switch (S1) that can be used to disconnect the current from the boat or connect the current to the boat. Current to the boat is limited by a 25Amp circuit breaker. The circuit is monitored by a combined Voltmeter / Ammeter.
2. Touch Points
Power is supplied from shore power and is directed to the House Battery Chargers Busbar.
3. Power Requirements
| Section | Component | Circuit Code |
Current |
|---|---|---|---|
| Circuit Provision | Shore Power Battery Charger | 17A | |
| Total Overall | 17A |
4. Parts List
| Ref. | Description |
|---|---|
| PS1 | Power Socket carrying 220V AC |
| C1 | Hi-Tec 200W Charger |
| S1 | On / Off Switch |
| CB1 | 25A circuit breaker |
| BB1, BB2 | Busbar connection points to the Battery Circuit |
| VA1 | Combined Voltmeter / Ammeter. Used to monitor circuit. |
| SH1 | Shunt for Ammeter |
| Up | > |